Marine Foam Board Comparison: Last-A-Foam TR vs Coosa vs Divinycell for Transoms and Stringers
For transoms and stringers, pick marine foam board by density and by how you build the part. LAST-A-FOAM® TR is unreinforced, high-density polyurethane foam that General Plastics stocks in 15, 20, and 24 lb/ft³ and cuts to custom shapes. Coosa is a polyurethane panel with fiberglass built in, and Divinycell is a PVC core that builders laminate between skins. Transoms take 15 to 24 lb/ft³ TR, and stringers take 6 to 20 lb/ft³.
1. What Is Marine Foam Board, and Why Is It Replacing Plywood in Transoms and Stringers?
Marine foam board is a closed-cell foam sheet that boat builders use as a structural core inside fiberglass laminates. LAST-A-FOAM® TR-Series foam will not absorb liquid water, and fiberglass laminating resins bond to it readily, with no mold-release contamination to inhibit bonding. That makes it a practical boat-building foam for parts that builders used to cut from plywood.
Plywood fails because water finds a way in. It enters through cracked gelcoat and through the screw and bolt holes drilled for hardware, and the wood swells, rots, and loses its grip on fasteners. Closed-cell polyurethane blocks that path, so damage stays at the point of impact instead of spreading through the panel. A foam transom or stringer does not gain weight from trapped water.
Marine-grade foam has to meet more than a water test. It must keep its strength when wet and resist the fuel, oil, and solvents found in a bilge. TR-Series foam is largely unaffected by solvents and paints, and polyurethane foam also resists diesel fuel, engine oil, and bilge cleaners. General Plastics makes TR in a range of densities, so a builder can match the foam to the load and avoid paying for strength a part will not use.
2. How Do Last-A-Foam TR, Coosa, and Divinycell Differ in Construction?
Last-A-Foam TR is bare, high-density polyurethane foam. Coosa is closed-cell polyurethane foam reinforced with continuous strand fiberglass and woven roving. Divinycell is a closed-cell PVC foam core sold in many grades and densities. The three products serve as a marine foam core in the same hull locations, but they start from different materials.
| LAST-A-FOAM® TR | Coosa Bluewater | Divinycell H | |
| Base material | Rigid polyurethane foam | Polyurethane foam | PVC foam |
| Reinforcement | None; no glass-fiber fillers | Continuous strand fiberglass and woven roving | None; laminated between skins |
| Density | 15, 20, 24 lb/ft³ | 20 and 26 to 28 lb/ft³ | 38 to 250 kg/m³ |
| Transom guidance | TR 15, 20 or 24 | Bluewater 26 preferred | Pick a grade from the H-series data table |
| Stringer guidance | 6 to 20 lb/ft³ | Bluewater 20 and Nautical 20 | Pick a grade from the H-series data table |
| How you buy it | Quote: sheets, CNC parts, kits | 4 x 8 ft sheets | Sheets through composite distributors |
Read the table as three answers to one question: who supplies the glass? With Coosa, the factory puts the glass inside the panel. With TR and Divinycell, the builder laminates the skins. TR and Coosa both use rigid polyurethane foam, so the real difference between them is reinforcement and form. Foam without glass fillers also machines cleanly and wears cutters more slowly, which matters when a shop cuts many transoms. When you compare marine foam board options, start with that question.
Density separates the three more than any other number. Coosa Bluewater 26 runs 26 to 28 lb/ft³, and Bluewater 20 runs 20 lb/ft³. Divinycell H grades span 38 to 250 kg/m³, with compressive strength rising from 0.45 to 6.2 MPa. TR 20 and TR 24 sit above the densest Divinycell grade, and TR 24 sits just below Bluewater 26. Coosa panels carry glass in their weight, and TR carries none, so a builder should compare the two by laminate schedule, not by density alone. Compare these figures only when each supplier measured them with the same method, such as the standard for compressive strength testing of rigid foam.
3. Which Marine Foam Board Is Best for Transoms?
The best marine foam board for a transom is high-density, closed-cell foam. For TR, General Plastics specifies 15, 20, or 24 lb/ft³ in transoms. Higher density resists the crushing force of the engine clamps, and the fiberglass skins supply the stiffness. The right grade depends on the stress the transom carries.
In foam core boat building, a transom is a sandwich of inner skin, foam block, and outer skin. A DIAB composite engineer writes that builders use higher-density, less friable polyurethane foams extensively in transoms because of their compressive strength. Coosa names Bluewater 26 as its preferred transom grade, and a Coosa board for transom replacement arrives as a finished panel with glass already inside. TR gives builders the block, and builders choose the skin layup around it. Download the TR-Marine technical data sheet for physical properties and handling details.
Why do wood transoms fail?
A transom sits at the waterline and carries the engine bolts, so water has two routes into the core. Cracked gelcoat opens one, and the bolt holes drilled for the engine bracket open the other. Plywood absorbs the water, swells, and rots, and the fasteners lose their grip. Once the core softens, the skins lose their backing.
How do you choose marine foam board density for a transom?
General Plastics lists three transom grades: TR 15, TR 20, and TR 24. The company advises builders to use materials matched to the anticipated stresses, which keeps cost in line. Send the engine weight, horsepower, and mounting type with your request, and General Plastics can confirm the grade for your hull. TR 24 ships in the most common stock sizes of the three. Designers who size sandwich laminates to small craft hull scantling requirements need tested core properties as inputs, so request the TR data sheet values before laying out the part.
How does TR bond in a transom laminate?
TR has a grain-free surface with no mold-release contamination, so polyester, vinyl ester, and epoxy resins bond to it directly. Vacuum the dust off machined surfaces before laminating. For high-density transom shapes, General Plastics offers a special surface treatment that allows even higher-strength bonds.
Where do you still need backing or higher density?
Foam does not carry every load alone. General Plastics recommends 24 to 30 lb/ft³ for I/O motor mounts, seat and steering wheel mounts, and hard points such as lifting lugs, cleats, and drain ports. The same DIAB engineer notes that wood can still serve where localized compression loads and through fittings make dense foam too costly. A patent filing adds that even high-density foam creeps slowly under constant point loads. Specify the 24 to 30 lb/ft³ grade at each hard point instead of relying on the main transom core.
4. What Is the Best Composite Boat Stringer Material, and What Density Should You Use?
Stringers need stiffness along their length and a core that bonds to the glass wrapped over it, so they work at lower densities than transoms. General Plastics recommends 6 to 20 lb/ft³ TR for boat stringers, depending on structural need. A rot-proof composite boat stringer material does not decay when water reaches the bilge.
Other suppliers point the same way on density for boat stringers. DIAB’s engineer lists lower-density polyurethane foam for formers and stringers. Coosa lists Nautical 20 and Bluewater 20 for stringers, decking, and similar parts. A stringer does not need the crush resistance of a transom, so builders save weight and cost by stepping down in density.
TR covers more than the stringer itself. General Plastics lists 10 to 15 lb/ft³ for decks and bulkheads, and 6 lb/ft³ trapezoidal beams for deck and bulkhead reinforcement. The company also cuts stringers as CNC parts and kits them, so a builder receives shaped pieces ready to lay into the hull.
5. Why Do Production Builders Specify Last-A-Foam TR?
Last-A-Foam TR is a rigid polyurethane foam that General Plastics formulates for FRP boat builders, and the company also supplies it as CNC-cut parts. A builder can run transoms, stringers, and hard points from one marine foam board family and change only the density. That keeps one resin system, one supplier, and one set of cutting tools across the structure.
TR contains no glass-fiber fillers, so shops can cut their own boat-building foam parts with ordinary tools. The foam is non-abrasive, and shops cut it with standard high-speed steel tools, water jets, or wood-carving tools. The grain-free structure gives the same strength in every direction, so a part cut from the edge of a sheet performs like one cut from the center.
TR 15 stocks at 24 x 48 x 96 inches (height by width by length), TR 20 at 18 x 48 x 96 inches, and TR 24 in five sizes. General Plastics cuts to sizes from 0.125 inch up to the stock height. The company has made polyurethane foam for more than 80 years and manufactures under ISO 9001:2015 and AS9100D certification.
6. When Is Coosa or Divinycell the Better Choice?

Coosa suits a one-off repair that needs a pre-skinned 4 x 8 panel. Divinycell suits lightweight sandwich panels and builds that require class approval. TR suits builders who laminate their own parts or need custom profiles.
Coosa saves layup steps. Coosa advises using the same thickness as the plywood it replaces, and the panel needs UV protection if sunlight reaches it. A carbide blade cuts it. A repair shop that replaces one transom a month gains little from a CNC kit and a lot from a panel it can pick up and cut.
Divinycell fits builders who need a marine foam core for hull and deck sandwich panels. DIAB lists pleasure craft and ship hulls among its applications, and the line carries DNV type approval as a sandwich core. A builder working to a class rule should check that approval first.
Fiberglass honeycomb core material also competes for panel work. General Plastics describes its polyurethane foams as alternatives to thermoplastic foam, honeycomb, wood, and metal cores. A transom clamps an engine, and a solid block of high-density foam carries that load through its full thickness.
7. How Do You Specify and Order Last-A-Foam TR?
Give General Plastics the application, density, size, and resin system for your marine foam board request, then ask for a quote. Include these details:
- Application: transom, stringer, hard point, or bulkhead
- Density: TR 15, 20, or 24, or a custom grade
- Sheet size or CNC profile
- Surface treatment for high-density transom shapes
- Resin system: polyester, vinyl ester, or epoxy
- Kitting and delivery schedule
The quote form accepts DXF, STEP, and PDF files, so a builder can send a transom or stringer drawing directly. Tell the team which boat building foam parts you plan to cut yourself and which you want cut and kitted. Request a sample to test the foam in your own laminate.
8. The Right Core, Settled
Match density to load. Use 15 to 24 lb/ft³ in transoms, 6 to 20 lb/ft³ in stringers, and 24 to 30 lb/ft³ at hard points. Choose Coosa for pre-skinned replacement panels, Divinycell for class-approved sandwich panels, and TR when you laminate and machine your own parts. Request a quote or review the TR-Marine product page.